Buffers and Solutions


Blocking Buffer for SuperProtein Substrate Surface Chemistry

Designed to block SuperProtein membrane based microarray surface chemistry prior to protein binding reactions for ultra low colorimetric background. For glass based protein microarrays use BlockIt.

Table of Contents

Introduction

Congratulations on taking a big step towards improving the economies of scale, quality and speed of your proteomics research. This booklet contains a complete set of protocols outlining the steps and principles needed to use the ArrayIt brand blocking buffer for SuperProtein membrane based surface chemistry. This product is design for use prior to incubation and hybridization reactions involving protein and DNA microarrays.

Quality Control

TeleChem assures the performance of these products, the finest scientific research went into their development.  Store at 4 Degrees Celsius, the product has a 1-year shelf life when handled and stored properly.

Product Description

The buffer is designed for blocking the portions of microarrays that can bind proteins after printing to eliminate background following the incubation or hybridization reaction of protein microarrays. Users will appreciate the following features:

  • Ultra-pure reagents used for buffer formulation
  • Purified by sterile filtration
  • Provided as 1X ready to use concentrate
  • Recommended for use on SuperProtein Substrates, but compatible with other protein membrane based microarray surface chemistries
  • Easy coverslip blocking procedure
  • 250 ml volume provided efficiently blocks thousands of microarrays
  • Will not react with proteins and DNA

Technical Assistance

Please contact us if you have any comments, suggestions, or if you need technical assistance. By electronic mail: arrayit@arrayit.com (under the subject heading, please type ArrayIt technical assistance). By telephone: (408) 744-1331, Monday–Friday PST 9:00am - 4:30pm. Please remember that we want to hear about your successes too!

Short Protocol for Protein Microarrays

Wash microarray with PBS and then incubate microarray in 1X blocking buffer under a coverslip for 1 hour prior to protein binding reactions.

Complete Protocol for Protein Microarrays

Once the printing process is complete, wash the printed microarrays 2 times for 15 minutes each in a High Throughput Wash Station in 1X PBS to remove unbound protein molecules and buffer components from the SuperProtein Substrates. Protein binding to the SuperProtein surface is stable and the microarrays can be washed, blocked and reacted without sufficient loss of coupled protein.  To block a microarray surface use a 1-hour incubation at room temperature in 1X buffer. Perform this reaction under a coverslip using 4 ul of BlockIt for every cm2 of coverslip area. A Hybridization Cassette can be used to keep the blocking reaction from drying out. SuperProtein blocking buffer will couple to un-reacted binding sites of the surface and prevent unspecific binding and background. After blocking, wash the microarrays to remove excess buffer. Washing three times for 1 min each at room temperature with 1X PBS in a High Throughput Wash Station.  DO NOT USE DETERGENT BASED buffers on the SuperProtein surface.

Troubleshooting Tips

If microarray shows high background...

  • Confirm that the intrinsic background of the microarray is low to start with.
  • Be sure to not let any sample dry on the microarray surface during the binding reaction.
  • Make sure to purify away unincorporated components of any labeling reactions.
  • Take care to block for the recommended time (1 hour).
  • Pay attention to the proper handling and shelf life of the buffer (1 year shelf life, Store at 4 C).
  • Do not skip washing the microarray after the blocking step.
  • If colorimetric labeling was used, be sure to optimize development times

Recommended Requirements:

Ordering Information

Product

Description

Catalog Number

Price (U.S. Dollars)*

SuperProtein Substrate blocking buffer

250 ml 1X blocking buffer for protein microarrays

SPBB

$175.00

 

 

Quantity 5-9

Quantity 10-19

Quantity 20+

5% Discount

10% Discount

15% Discount

* All prices plus shipping via Federal Express or US Postal Service Priority Mail. ***** International pricing may vary as much as 30% (or more depending on country) due to import duties, stocking fees and technical support.

Email: arrayit@arrayit.com

To order ArrayIt Brand Products: call 408-744-1331, fax 408-744-1711 or click on the button below to go directly to the purchase page.

 

Warranty

ArrayIt brand products have been scientifically developed and are sold for research purposes only. ArrayIt products are not for use in human diagnostics or for drug purposes, nor are they to be administered to humans in any way. Extreme care and exact attention should be practiced in the use of the materials described herein. All ArrayIt brand products are subject to extensive quality control and are guaranteed to perform as described when used properly. Any problems with any ArrayIt brand product should be reported to TeleChem immediately. TeleChem’s liability is limited to the replacement of the product, or a full refund. Any misuse of this product is the full responsibility of the user, and TeleChem makes no warranty or guarantee under such circumstances.